Specials Call Now Contact Us Book Online

Heating Repair in Kutztown, PA

moyer-bull-dog-with-red-stripe

Heating Repair in Kutztown PA — When the Heat’s Out, We’re On the Way

Reliable Heating Repair in Kutztown, PA — Stay Warm When It Matters Most

When the cold hits Kutztown and your heater stops working, you don’t have time to wait around. You need fast, local heating repair in Kutztown, PA that gets your system running again and keeps your home safe and comfortable. At Moyer Total Indoor Comfort, we make heating problems disappear — quickly and affordably. For immediate help, call 8472412834.

Why Timely Heating Repair in Kutztown, PA Is So Important

Your heating system works hardest during Pennsylvania’s coldest months, and that’s when breakdowns usually happen. Getting heating repair in Kutztown, PA at the first sign of trouble helps prevent bigger issues and keeps energy bills from skyrocketing. Many homeowners ignore early warning signs like weak airflow, strange noises, or rooms that won’t stay warm. Acting early with a trusted local expert means lower repair costs and peace of mind all winter long.

Trusted Local Experts for Heating Repair in Kutztown, PA

At Moyer Total Indoor Comfort, we’ve been helping Kutztown residents stay comfortable for decades. Our team lives and works right here, so when you search for heating repair in Kutztown, PA, you’re reaching real neighbors who care about your comfort. We understand the unique challenges of older Pennsylvania homes and the demands of modern high-efficiency heating systems.

Our technicians arrive on time, explain what’s happening with your system, and fix it right — the first time. We service gas furnaces, electric heaters, heat pumps, and boilers from every major brand.

You can expect:

Common Problems Requiring Heating Repair in Kutztown, PA

When homeowners call us for heating repair in Kutztown, PA, the same issues appear again and again. The good news? Most are fixable on the spot.

These are all clear signs your heating system is under strain and needs professional care. Our experts will find the problem, explain your options, and get your home warm again before the chill sets in.

What to Expect from Professional Heating Repair in Kutztown, PA

When you schedule heating repair in Kutztown, PA, we start with a detailed inspection to uncover what’s really causing the problem. Our process includes:

  1. Checking the thermostat and control systems
  2. Inspecting and cleaning air filters
  3. Testing safety switches and burners
  4. Calibrating airflow and measuring system efficiency
  5. Performing repairs and verifying everything runs smoothly

Before we leave, we’ll give you easy maintenance tips to help prevent future breakdowns — and we’ll always answer your questions clearly, without using confusing technical talk.

Avoid Costly Repairs with Heating Maintenance in Kutztown, PA

Routine maintenance keeps your heating system working at its best. Scheduling annual tune-ups in the fall ensures your furnace or heat pump is ready when temperatures drop. During maintenance, we clean key components, lubricate moving parts, and check for early signs of wear. This simple step helps you avoid emergency calls for heating repair in Kutztown, PA when you need heat the most.

Ask about our HVAC Service Agreements to get scheduled maintenance, discounted repairs, and priority service — a simple way to protect your comfort all year long.

Serving More Than Just Heating Repair in Kutztown, PA

Moyer Total Indoor Comfort proudly serves homeowners throughout Berks County, including Fleetwood, Allentown, and Reading. We’re known for quick, professional heating repair and friendly customer service. If your system breaks down, we’ll be there fast to restore warmth and safety to your home.

Call now at 8472412834 or schedule service online. We make staying comfortable easy — no waiting, no stress, just dependable heating repair in Kutztown, PA whenever you need it.

Frequently Asked Questions About Heating Repair in Kutztown, PA

Q: How do I know I need heating repair in Kutztown, PA?
If your heater runs constantly, blows cold air, or makes unusual noises, it’s time to schedule a repair. Catching issues early prevents more serious problems later.

Q: How fast can someone come out for heating repair in Kutztown, PA?
Most service calls in Kutztown are handled the same day. We prioritize no-heat situations, especially during freezing weather.

Q: What’s the average cost of heating repair in Kutztown, PA?
It depends on the part and labor, but we provide clear pricing before any work begins so there are no surprises.

Q: Can I fix my heating system myself?
Some simple steps, like replacing filters, help maintain efficiency, but most repairs should be handled by a licensed technician for safety and performance.

Q: Do you repair all types of heating systems?
Yes. We service gas furnaces, electric heaters, boilers, and heat pumps from all major manufacturers.

Q: Does regular maintenance really reduce the need for heating repair in Kutztown, PA?
Absolutely. A yearly inspection helps find small problems before they turn into major breakdowns, saving time and money.

Q: How can I prevent emergency heating repair in Kutztown, PA?
Schedule maintenance once a year, keep vents clear, and listen for unusual sounds. Consistent care keeps your system running longer and more reliably.

Learn More About Your Home Comfort

Furnace Repair in Kutztown, PA

Find out how our furnace repair services keep your home warm and efficient through Pennsylvania winters.

Water Heater Repair in Kutztown, PA

Learn how to solve common hot water problems with our local experts.

HVAC Service Agreements

See how regular service plans help you save money and avoid unexpected repairs.

Indoor Air Quality Services in Kutztown, PA

Discover how we can make the air inside your home cleaner and healthier year-round.

Call Now for Professional Heating Repair in Kutztown, PA

When your heating system struggles, don’t wait until it quits completely. Call 8472412834 today or visit our Contact Us page to schedule service. Moyer Total Indoor Comfort delivers fast, honest, and professional heating repair in Kutztown, PA that keeps your family warm when it matters most.

 

Recent Jobs and Reviews in Kutztown, PA

Rated 5.0 out of 5 stars based on 88 customer reviews

Customers say: The overall sentiment is overwhelmingly positive, marked by genuine appreciation and enthusiasm for the service received. Customers consistently praise the speed and punctuality of the work, with many noting quick response times, on-time arrivals, and efficient completion of jobs, including urgent situations where timely help made a real difference. Another dominant theme is the professionalism and courtesy of the staff, who are repeatedly described as friendly, polite, respectful, and pleasant to work with. Technicians are widely regarded as knowledgeable and skilled, with many reviewers highlighting their ability to diagnose problems accurately, explain technical details in clear and understandable terms, and patiently answer questions. Customers also value the thoroughness, cleanliness, and attention to detail shown during inspections, repairs, and installations. Many express long-term loyalty, referencing years of ongoing maintenance relationships and strong word-of-mouth recommendations, which reflects deep trust and satisfaction. The tone throughout is warm, grateful, and confident, with a strong sense that customers feel well cared for, informed, and eager to recommend the business to others.

Kutztown, PA at a glance

Moyer Total Indoor Comfort has completed 25 jobs in Kutztown, PA between October 2026 and November 2026.

The 25 customer reviews shown here average 5.0 out of 5.

The most recent job was on November 9, 2026.

Moyer Total Indoor Comfort has completed 306 jobs in Kutztown, PA in the last 12 months. The first job there was in November 2023.

Job Locations and Reviews

Inspected the Hague WaterMax MXQ water softener, which was found flooded with water in the brine tank and had not regenerated in an unknown period. Evaluated the unit's operation and the surrounding plumbing, noting significant corrosion and oxidation on the copper supply lines and fittings along with deteriorated pipe insulation in the mechanical area. Performed diagnostic testing on the softener to address the brine tank overfill and restore proper regeneration function.
Inspected the Hague WaterMax MXQ water softener, which was found flooded with water in the brine tank and had not regenerated in an unknown period. Evaluated the unit's operation and the surrounding plumbing, noting significant corrosion and oxidation on the copper supply lines and fittings along with deteriorated pipe insulation in the mechanical area. Performed diagnostic testing on the softener to address the brine tank overfill and restore proper regeneration function.
Jonathan K.
Jonathan K. Checked in
Inspected the Hague WaterMax MXQ water softener, which was found flooded with water in the brine tank and had not regenerated in an unknown period. Evaluated the unit's operation and the surrounding plumbing, noting significant corrosion and oxidation on the copper supply lines and fittings along with deteriorated pipe insulation in the mechanical area. Performed diagnostic testing on the softener to address the brine tank overfill and restore proper regeneration function.
Kutztown, PA 19530
Responded to a no-water complaint and found the well pressure tank at zero pressure, with the pressure switch, manifold, and gauge assembly at the tank base showing signs of moisture and mineral residue. Diagnosed the loss of system pressure as a likely well pump issue and determined the pump, located in a pit in the driveway, needs to be pulled for further inspection and testing.
Responded to a no-water complaint and found the well pressure tank at zero pressure, with the pressure switch, manifold, and gauge assembly at the tank base showing signs of moisture and mineral residue. Diagnosed the loss of system pressure as a likely well pump issue and determined the pump, located in a pit in the driveway, needs to be pulled for further inspection and testing.
Steven M.
Steven M. Checked in
Responded to a no-water complaint and found the well pressure tank at zero pressure, with the pressure switch, manifold, and gauge assembly at the tank base showing signs of moisture and mineral residue. Diagnosed the loss of system pressure as a likely well pump issue and determined the pump, located in a pit in the driveway, needs to be pulled for further inspection and testing.
Kutztown, PA 19530
Performed a heating-mode tune-up on an existing Ducane heat pump system. Measured supply air temperature at 105°F with a pocket thermometer and checked compressor/condenser electrical draw with a clamp meter at the outdoor unit to verify proper operation. System was found to be operating normally during the inspection.
Performed a heating-mode tune-up on an existing Ducane heat pump system. Measured supply air temperature at 105°F with a pocket thermometer and checked compressor/condenser electrical draw with a clamp meter at the outdoor unit to verify proper operation. System was found to be operating normally during the inspection.
Roberto H.
Roberto H. Checked in
Performed a heating-mode tune-up on an existing Ducane heat pump system. Measured supply air temperature at 105°F with a pocket thermometer and checked compressor/condenser electrical draw with a clamp meter at the outdoor unit to verify proper operation. System was found to be operating normally during the inspection.
Kutztown, PA 19530
Performed an annual oil-fired boiler cleaning and tune-up, and inspected the boiler's pressure relief valve following a reported discharge event. Evaluated the relief valve, expansion tank, and associated piping and zone valves to identify the cause of the overpressure condition, and reviewed boiler operation and safety practices with the new homeowners.
Performed an annual oil-fired boiler cleaning and tune-up, and inspected the boiler's pressure relief valve following a reported discharge event. Evaluated the relief valve, expansion tank, and associated piping and zone valves to identify the cause of the overpressure condition, and reviewed boiler operation and safety practices with the new homeowners.
Roberto H.
Roberto H. Checked in
Performed an annual oil-fired boiler cleaning and tune-up, and inspected the boiler's pressure relief valve following a reported discharge event. Evaluated the relief valve, expansion tank, and associated piping and zone valves to identify the cause of the overpressure condition, and reviewed boiler operation and safety practices with the new homeowners.
Kutztown, PA 19530
Performed an annual oil maintenance inspection on a 2009 New Yorker hydronic boiler, including examination of the oil burner, flue connection, circulator pumps, expansion tank, and associated piping and controls. System appeared in good overall condition with no frost, rust, or visible damage; a minor moisture droplet was noted near the insulated piping above the equipment for monitoring.
Performed an annual oil maintenance inspection on a 2009 New Yorker hydronic boiler, including examination of the oil burner, flue connection, circulator pumps, expansion tank, and associated piping and controls. System appeared in good overall condition with no frost, rust, or visible damage; a minor moisture droplet was noted near the insulated piping above the equipment for monitoring.
Bob L.
Bob L. Checked in
Performed an annual oil maintenance inspection on a 2009 New Yorker hydronic boiler, including examination of the oil burner, flue connection, circulator pumps, expansion tank, and associated piping and controls. System appeared in good overall condition with no frost, rust, or visible damage; a minor moisture droplet was noted near the insulated piping above the equipment for monitoring.
Kutztown, PA 19530
Diagnosed a 19-year-old Carrier heat pump system with reduced heating output and inspected the air handler, finding the evaporator coil heavily corroded with rust and oxidation on the fins and copper return bends, along with a dirty, stained drain pan and a dirty blower assembly. Documented the condition of the coil, drain pan, and blower with photos; the corrosion and age of the unit indicate reduced heat transfer and airflow, and system replacement is recommended.
Diagnosed a 19-year-old Carrier heat pump system with reduced heating output and inspected the air handler, finding the evaporator coil heavily corroded with rust and oxidation on the fins and copper return bends, along with a dirty, stained drain pan and a dirty blower assembly. Documented the condition of the coil, drain pan, and blower with photos; the corrosion and age of the unit indicate reduced heat transfer and airflow, and system replacement is recommended.
Roberto H.
Roberto H. Checked in
Diagnosed a 19-year-old Carrier heat pump system with reduced heating output and inspected the air handler, finding the evaporator coil heavily corroded with rust and oxidation on the fins and copper return bends, along with a dirty, stained drain pan and a dirty blower assembly. Documented the condition of the coil, drain pan, and blower with photos; the corrosion and age of the unit indicate reduced heat transfer and airflow, and system replacement is recommended.
Kutztown, PA 19530
Performed a heating tune-up and inspection on a geothermal split system with a Carrier air handler, including visual checks of the refrigerant/loop piping, insulation, condensate drain fitting, ductwork connections, circulation pump, and associated controls. Verified system operation in heating mode with no leaks, corrosion, or abnormalities observed; unit age and model could not be confirmed, and the system is operating normally.
Performed a heating tune-up and inspection on a geothermal split system with a Carrier air handler, including visual checks of the refrigerant/loop piping, insulation, condensate drain fitting, ductwork connections, circulation pump, and associated controls. Verified system operation in heating mode with no leaks, corrosion, or abnormalities observed; unit age and model could not be confirmed, and the system is operating normally.
Bob L.
Bob L. Checked in
Performed a heating tune-up and inspection on a geothermal split system with a Carrier air handler, including visual checks of the refrigerant/loop piping, insulation, condensate drain fitting, ductwork connections, circulation pump, and associated controls. Verified system operation in heating mode with no leaks, corrosion, or abnormalities observed; unit age and model could not be confirmed, and the system is operating normally.
Kutztown, PA 19530
Removed the existing 48" baseboard register and installed a new Hart & Cooley 48" white baseboard unit, then installed a second matching baseboard unit, relocating it to allow the adjacent cabinet to open fully. Verified both units were securely mounted and properly positioned along the wall.
Removed the existing 48" baseboard register and installed a new Hart & Cooley 48" white baseboard unit, then installed a second matching baseboard unit, relocating it to allow the adjacent cabinet to open fully. Verified both units were securely mounted and properly positioned along the wall.
Roberto H.
Roberto H. Checked in
Removed the existing 48" baseboard register and installed a new Hart & Cooley 48" white baseboard unit, then installed a second matching baseboard unit, relocating it to allow the adjacent cabinet to open fully. Verified both units were securely mounted and properly positioned along the wall.
Kutztown, PA 19530
Performed a complete oil boiler cleaning and inspection on the existing system, including a full component check of the burner, controls, safety circuit, ignition and flame sensing, oil piping, fuel pump, expansion tank, and pressure relief device. Verified the burner nozzle (0.75 GPH, 80° A) and recorded voltage, amp draw, fuel pump pressure, temperature split, and combustion/flue gas readings, with the boiler temperature/pressure gauge also checked during the visit.
Performed a complete oil boiler cleaning and inspection on the existing system, including a full component check of the burner, controls, safety circuit, ignition and flame sensing, oil piping, fuel pump, expansion tank, and pressure relief device. Verified the burner nozzle (0.75 GPH, 80° A) and recorded voltage, amp draw, fuel pump pressure, temperature split, and combustion/flue gas readings, with the boiler temperature/pressure gauge also checked during the visit.
Adam M.
Adam M. Checked in
Performed a complete oil boiler cleaning and inspection on the existing system, including a full component check of the burner, controls, safety circuit, ignition and flame sensing, oil piping, fuel pump, expansion tank, and pressure relief device. Verified the burner nozzle (0.75 GPH, 80° A) and recorded voltage, amp draw, fuel pump pressure, temperature split, and combustion/flue gas readings, with the boiler temperature/pressure gauge also checked during the visit.
Kutztown, PA 19530
Performed a complete tune-up and inspection on a gas condensing boiler (ECO TEC 110C), verifying proper operation and that the DHW preheat function was active and reaching its 140°F setpoint. Inspected the system piping, valves, and pressure/temperature gauge, noting oxidation and corrosion on the copper piping and brass fittings; the customer declined additional plumbing repairs at this time. The boiler is operating normally with no visible damage.
Performed a complete tune-up and inspection on a gas condensing boiler (ECO TEC 110C), verifying proper operation and that the DHW preheat function was active and reaching its 140°F setpoint. Inspected the system piping, valves, and pressure/temperature gauge, noting oxidation and corrosion on the copper piping and brass fittings; the customer declined additional plumbing repairs at this time. The boiler is operating normally with no visible damage.
Adam M.
Adam M. Checked in
Performed a complete tune-up and inspection on a gas condensing boiler (ECO TEC 110C), verifying proper operation and that the DHW preheat function was active and reaching its 140°F setpoint. Inspected the system piping, valves, and pressure/temperature gauge, noting oxidation and corrosion on the copper piping and brass fittings; the customer declined additional plumbing repairs at this time. The boiler is operating normally with no visible damage.
Kutztown, PA 19530
Performed a preventative maintenance heating inspection on a Nortek gas furnace (install date unknown), including a visual inspection of the control compartment and low-voltage wiring and a clamp meter amperage check on the unit's electrical circuit, which measured 1.30 A AC. Noted disorganized low-voltage wiring with multiple wire-nut splices, dust accumulation in the cabinet, and moisture on the motor/capacitor housing, which should be monitored at future visits.
Performed a preventative maintenance heating inspection on a Nortek gas furnace (install date unknown), including a visual inspection of the control compartment and low-voltage wiring and a clamp meter amperage check on the unit's electrical circuit, which measured 1.30 A AC. Noted disorganized low-voltage wiring with multiple wire-nut splices, dust accumulation in the cabinet, and moisture on the motor/capacitor housing, which should be monitored at future visits.
Adam M.
Adam M. Checked in
Performed a preventative maintenance heating inspection on a Nortek gas furnace (install date unknown), including a visual inspection of the control compartment and low-voltage wiring and a clamp meter amperage check on the unit's electrical circuit, which measured 1.30 A AC. Noted disorganized low-voltage wiring with multiple wire-nut splices, dust accumulation in the cabinet, and moisture on the motor/capacitor housing, which should be monitored at future visits.
Kutztown, PA 19530
Performed a first-time inspection and tune-up on the gas furnace, including the gas valve assembly, burner components, and wiring connections. Found moderate rust and corrosion on interior panels beneath the gas valve, along with heavy dust and soot buildup on the burner assembly and surrounding components. Replaced the electric baseboard thermostat, checked the water heater fitting installed earlier this year for corrosion, and left a membership brochure with the customer.
Performed a first-time inspection and tune-up on the gas furnace, including the gas valve assembly, burner components, and wiring connections. Found moderate rust and corrosion on interior panels beneath the gas valve, along with heavy dust and soot buildup on the burner assembly and surrounding components. Replaced the electric baseboard thermostat, checked the water heater fitting installed earlier this year for corrosion, and left a membership brochure with the customer.
Bob L.
Bob L. Checked in
Performed a first-time inspection and tune-up on the gas furnace, including the gas valve assembly, burner components, and wiring connections. Found moderate rust and corrosion on interior panels beneath the gas valve, along with heavy dust and soot buildup on the burner assembly and surrounding components. Replaced the electric baseboard thermostat, checked the water heater fitting installed earlier this year for corrosion, and left a membership brochure with the customer.
Kutztown, PA 19530
Performed a complete oil boiler tune-up, including cleaning the burner and boiler, replacing the 1.25 x 80A nozzle, and verifying electrical readings, fuel pump pressure, expansion tank pressure, and flue gas temperature. Combustion testing showed 80.7% efficiency, with the system operating properly. Recommended replacing the pressure relief valve, which is over five years old, and noted the domestic hot water anti-scald device for follow-up.
Performed a complete oil boiler tune-up, including cleaning the burner and boiler, replacing the 1.25 x 80A nozzle, and verifying electrical readings, fuel pump pressure, expansion tank pressure, and flue gas temperature. Combustion testing showed 80.7% efficiency, with the system operating properly. Recommended replacing the pressure relief valve, which is over five years old, and noted the domestic hot water anti-scald device for follow-up.
Adam M.
Adam M. Checked in
Performed a complete oil boiler tune-up, including cleaning the burner and boiler, replacing the 1.25 x 80A nozzle, and verifying electrical readings, fuel pump pressure, expansion tank pressure, and flue gas temperature. Combustion testing showed 80.7% efficiency, with the system operating properly. Recommended replacing the pressure relief valve, which is over five years old, and noted the domestic hot water anti-scald device for follow-up.
Kutztown, PA 19530
Replaced the faulty gas valve on the furnace, which was intermittently failing to operate unless tapped. After installation, verified gas supply and manifold pressure with a digital manometer, confirming a proper reading within specification. Inspected the surrounding gas train, inducer assembly, and pressure switch wiring, and confirmed normal operation.
Replaced the faulty gas valve on the furnace, which was intermittently failing to operate unless tapped. After installation, verified gas supply and manifold pressure with a digital manometer, confirming a proper reading within specification. Inspected the surrounding gas train, inducer assembly, and pressure switch wiring, and confirmed normal operation.
Roberto H.
Roberto H. Checked in
Replaced the faulty gas valve on the furnace, which was intermittently failing to operate unless tapped. After installation, verified gas supply and manifold pressure with a digital manometer, confirming a proper reading within specification. Inspected the surrounding gas train, inducer assembly, and pressure switch wiring, and confirmed normal operation.
Kutztown, PA 19530
Installed new water supply and waste piping with surface-mounted washer valves, relocated the dryer power receptacle, and extended the existing dryer vent to serve a main-level laundry room, accessing piping routes through the basement wall adjacent to the air handler. Supplied and installed a washer drain pan piped to the basement laundry tub with no trap in the line, then relocated the washer and dryer from the basement to the first-floor room and completed final connections.
Installed new water supply and waste piping with surface-mounted washer valves, relocated the dryer power receptacle, and extended the existing dryer vent to serve a main-level laundry room, accessing piping routes through the basement wall adjacent to the air handler. Supplied and installed a washer drain pan piped to the basement laundry tub with no trap in the line, then relocated the washer and dryer from the basement to the first-floor room and completed final connections.
Bob L.
Bob L. Checked in
Installed new water supply and waste piping with surface-mounted washer valves, relocated the dryer power receptacle, and extended the existing dryer vent to serve a main-level laundry room, accessing piping routes through the basement wall adjacent to the air handler. Supplied and installed a washer drain pan piped to the basement laundry tub with no trap in the line, then relocated the washer and dryer from the basement to the first-floor room and completed final connections.
Kutztown, PA 19530
Performed a preseason tune-up on the propane-fired furnace, including inspection of the burner assembly and flame characteristics, with attention to proper combustion given the customer's concern about possible blockage and carbon monoxide. Verified blower motor amperage with a clamp meter, checked electrical connections and control board wiring, and confirmed the unit was operating properly.
Performed a preseason tune-up on the propane-fired furnace, including inspection of the burner assembly and flame characteristics, with attention to proper combustion given the customer's concern about possible blockage and carbon monoxide. Verified blower motor amperage with a clamp meter, checked electrical connections and control board wiring, and confirmed the unit was operating properly.
Adam M.
Adam M. Checked in
Performed a preseason tune-up on the propane-fired furnace, including inspection of the burner assembly and flame characteristics, with attention to proper combustion given the customer's concern about possible blockage and carbon monoxide. Verified blower motor amperage with a clamp meter, checked electrical connections and control board wiring, and confirmed the unit was operating properly.
Kutztown, PA 19530
Replaced the failed Ultra-Aire dehumidifier/ventilation system controller, which was damaged by a power surge, with the new unit. Mounted the controller on the existing junction box at the ductwork, reconnected the control wiring, and verified the display powered up and the system responded to commands.
Replaced the failed Ultra-Aire dehumidifier/ventilation system controller, which was damaged by a power surge, with the new unit. Mounted the controller on the existing junction box at the ductwork, reconnected the control wiring, and verified the display powered up and the system responded to commands.
Bob L.
Bob L. Checked in
Replaced the failed Ultra-Aire dehumidifier/ventilation system controller, which was damaged by a power surge, with the new unit. Mounted the controller on the existing junction box at the ductwork, reconnected the control wiring, and verified the display powered up and the system responded to commands.
Kutztown, PA 19530
Inspected the washing machine drain connection after a report of water on the floor behind the unit. Found the corrugated drain hose seated in the top of the vertical PVC standpipe with a rubber collar, connected to the P-trap assembly, with staining and debris buildup visible around the lower pipe fittings and the wall. Treated the drain line with acid to clear buildup and restore proper drainage flow, which addresses the likely cause of the standpipe overflow behind the machine.
Inspected the washing machine drain connection after a report of water on the floor behind the unit. Found the corrugated drain hose seated in the top of the vertical PVC standpipe with a rubber collar, connected to the P-trap assembly, with staining and debris buildup visible around the lower pipe fittings and the wall. Treated the drain line with acid to clear buildup and restore proper drainage flow, which addresses the likely cause of the standpipe overflow behind the machine.
Jonathan K.
Jonathan K. Checked in
Inspected the washing machine drain connection after a report of water on the floor behind the unit. Found the corrugated drain hose seated in the top of the vertical PVC standpipe with a rubber collar, connected to the P-trap assembly, with staining and debris buildup visible around the lower pipe fittings and the wall. Treated the drain line with acid to clear buildup and restore proper drainage flow, which addresses the likely cause of the standpipe overflow behind the machine.
Kutztown, PA 19530
Performed a complete oil burner tune-up on the existing Kneck 2000 unit, including cleaning the heavily sooted flue pipe and burner components, replacing the nozzle with a .75 x 70B, and installing a new Beckett spin-on pressure filter element. Verified burner motor operation with an amperage reading of 0.76 A, confirming normal electrical draw.
Performed a complete oil burner tune-up on the existing Kneck 2000 unit, including cleaning the heavily sooted flue pipe and burner components, replacing the nozzle with a .75 x 70B, and installing a new Beckett spin-on pressure filter element. Verified burner motor operation with an amperage reading of 0.76 A, confirming normal electrical draw.
Bob L.
Bob L. Checked in
Performed a complete oil burner tune-up on the existing Kneck 2000 unit, including cleaning the heavily sooted flue pipe and burner components, replacing the nozzle with a .75 x 70B, and installing a new Beckett spin-on pressure filter element. Verified burner motor operation with an amperage reading of 0.76 A, confirming normal electrical draw.
Kutztown, PA 19530
Inspected loose toilets and removed one fixture, exposing a corroded closet flange with old wax ring residue set into a rotted, water-damaged subfloor. Because the damaged flooring cannot support a proper reset, the toilet was left disconnected pending subfloor repair, and the drain opening was secured. The drain stop retrieval and UV bulb replacement were not completed during this visit.
Inspected loose toilets and removed one fixture, exposing a corroded closet flange with old wax ring residue set into a rotted, water-damaged subfloor. Because the damaged flooring cannot support a proper reset, the toilet was left disconnected pending subfloor repair, and the drain opening was secured. The drain stop retrieval and UV bulb replacement were not completed during this visit.
Jonathan K.
Jonathan K. Checked in
Inspected loose toilets and removed one fixture, exposing a corroded closet flange with old wax ring residue set into a rotted, water-damaged subfloor. Because the damaged flooring cannot support a proper reset, the toilet was left disconnected pending subfloor repair, and the drain opening was secured. The drain stop retrieval and UV bulb replacement were not completed during this visit.
Kutztown, PA 19530
Performed a heat pump tune-up on a Lennox system installed in 2018, inspecting the indoor air handler and outdoor condenser including the electrical compartment, contactor, capacitor, and wiring. Observed heavy mold/mildew staining and buildup on the blower housing and dust accumulation on the motor and wiring, and documented blower wheel cleaning as a recommended repair for system efficiency and indoor air quality.
Performed a heat pump tune-up on a Lennox system installed in 2018, inspecting the indoor air handler and outdoor condenser including the electrical compartment, contactor, capacitor, and wiring. Observed heavy mold/mildew staining and buildup on the blower housing and dust accumulation on the motor and wiring, and documented blower wheel cleaning as a recommended repair for system efficiency and indoor air quality.
Wells R.
Wells R. Checked in
Performed a heat pump tune-up on a Lennox system installed in 2018, inspecting the indoor air handler and outdoor condenser including the electrical compartment, contactor, capacitor, and wiring. Observed heavy mold/mildew staining and buildup on the blower housing and dust accumulation on the motor and wiring, and documented blower wheel cleaning as a recommended repair for system efficiency and indoor air quality.
Kutztown, PA 19530
Relocated the Lennox condenser unit and raised it 4"-6" to accommodate the new deck construction, ensuring proper clearance and airflow around the unit. Inspected the heat tape beneath the home and verified it was functioning properly. Unit was left clean and intact, with no visible damage, rust, or frost.
Relocated the Lennox condenser unit and raised it 4"-6" to accommodate the new deck construction, ensuring proper clearance and airflow around the unit. Inspected the heat tape beneath the home and verified it was functioning properly. Unit was left clean and intact, with no visible damage, rust, or frost.
Bob L.
Bob L. Checked in
Relocated the Lennox condenser unit and raised it 4"-6" to accommodate the new deck construction, ensuring proper clearance and airflow around the unit. Inspected the heat tape beneath the home and verified it was functioning properly. Unit was left clean and intact, with no visible damage, rust, or frost.
Kutztown, PA 19530
Kutztown, PA - Responded to a drain backup recurring from a prior service call. Located and accessed the exterior sewer cleanout, removing the heavily corroded cast-iron cleanout cover to gain direct access to the line, then cleared the blockage to restore proper drainage flow. Documented the severely rusted cleanout housing and cover, which are deteriorated and may warrant replacement to prevent future access issues.
Jonathan K.
Jonathan K. Checked in
Responded to a drain backup recurring from a prior service call. Located and accessed the exterior sewer cleanout, removing the heavily corroded cast-iron cleanout cover to gain direct access to the line, then cleared the blockage to restore proper drainage flow. Documented the severely rusted cleanout housing and cover, which are deteriorated and may warrant replacement to prevent future access issues.
Kutztown, PA 19530
Replaced the existing water heater with a new Bradford White unit, reconnecting the hot and cold supply lines with copper piping and ball isolation valves, and routing the flue and discharge piping to code. Also replaced the basement shutoff valve serving the exterior hose spigot to restore proper isolation and operation.
Replaced the existing water heater with a new Bradford White unit, reconnecting the hot and cold supply lines with copper piping and ball isolation valves, and routing the flue and discharge piping to code. Also replaced the basement shutoff valve serving the exterior hose spigot to restore proper isolation and operation.
Jonathan K.
Jonathan K. Checked in
Replaced the existing water heater with a new Bradford White unit, reconnecting the hot and cold supply lines with copper piping and ball isolation valves, and routing the flue and discharge piping to code. Also replaced the basement shutoff valve serving the exterior hose spigot to restore proper isolation and operation.
Kutztown, PA 19530
Performed a seasonal tune-up on the Lennox air conditioning system, inspecting the outdoor condenser unit, fan assembly, electrical disconnect, and conduit connections. Noted heavy vegetation growth against the condenser sides and recommended clearing weeds and debris to restore proper airflow and clearance. Verified system performance and calculated operating readings to confirm the unit is functioning within normal parameters.
Performed a seasonal tune-up on the Lennox air conditioning system, inspecting the outdoor condenser unit, fan assembly, electrical disconnect, and conduit connections. Noted heavy vegetation growth against the condenser sides and recommended clearing weeds and debris to restore proper airflow and clearance. Verified system performance and calculated operating readings to confirm the unit is functioning within normal parameters.
Roberto H.
Roberto H. Checked in
Performed a seasonal tune-up on the Lennox air conditioning system, inspecting the outdoor condenser unit, fan assembly, electrical disconnect, and conduit connections. Noted heavy vegetation growth against the condenser sides and recommended clearing weeds and debris to restore proper airflow and clearance. Verified system performance and calculated operating readings to confirm the unit is functioning within normal parameters.
Kutztown, PA 19530
Review
Guys did a great job cleaned up area.
Richard - Kutztown, PA 19530
Review
The whole team from Ron to Roberto and his partner (forgot his name) made it possible for us to have AC on again this Friday afternoon. That is why we use Moyer Comfort to service us. Thank you all so very very much.
Ken - Kutztown, PA 19530
Review
Always prompt and professional
Chris - Kutztown, PA 19530
Review
As always, Moyer is fast and efficient in diagnosing the issue and repairing it. John and his team were professional and got the job done in a timely manner.
Kelly - Kutztown, PA 19530
Review
Excellent Service
Elaine - Kutztown, PA 19530
Review
Fixed our AC in timely manner
Scott - Kutztown, PA 19530
Review
As always, Moyer Total Indoor Comfort did an excellent job at repairing my bathroom sink and leaking shower. John was very professional and knowledgeable. Thanks for great and reliable service.
Kelly - Kutztown, PA 19530
Review
Adam was great. Did a thorough job servicing our unit. He explained everything in detail including the estimates for future service.
Libby - Kutztown, PA 19530
Review
Had an AC issue. Roberto diagnosed that the switch failed shutting my AC system down. He replaced the switch and my AC unit is now running again.
Frank - Kutztown, PA 19530
Review
Looking for a new service tech. Good service may have found one.
Robert - Kutztown, PA 19530
Review
Tech was on time, very polite, explainded what he was testing.
Michael - Kutztown, PA 19530
Review
Great service
Jeremiah - Kutztown, PA 19530
Review
John was quick to fix the issue and was really nice
Priscilla - Kutztown, PA 19530
Review
Polite, personable and punctual. Respected my home.
Kevin - Kutztown, PA 19530
Review
Well done, fully explained service. Very competent technician. Appreciate the way the booking for service was handled. Accommodated my schedule. By
Kelley - Kutztown, PA 19530
Review
Great service
Joe - Kutztown, PA 19530
Review
Great job
Kathleen - Kutztown, PA 19530
Review
Very professional guys, very nice to do my work not all done must come back can’t rate price yet
Marsha Cressman - Kutztown, PA 19530
Review
Job done
Pasquale - Kutztown, PA 19530
Review
Adam was very professional and provided clarity on each step of the repair process. Will definitely keep your team as a preferred service. 😊
George - Kutztown, PA 19530
Review
The crew did an amazing and professional job at a competitive price
Matt G - Kutztown, PA 19530
Review
As always, Roberto was amazing! He took care of the problem, with honesty, efficiency, and kindness.
Ken - Kutztown, PA 19530
Review
Fixed our issue very quickly!
Alicia - Kutztown, PA 19530
Review
Moyer’s Total Indoor Comfort is top notch! The service technicians are very knowledgeable and careful not to track any debris into the home when they need to go in and out. Jonathan took the time to explain everything and answered all of my questions. He was a pleasure to work with. Products are superior!
MaryB - Kutztown, PA 19530
Response from Moyer Total Indoor Comfort:

Thank you for the kinds words, it means the world to us that our customers are satisfied with our products and services. We are thrilled that you had a great experience with Jon and Wyatt.

Review
He was great
Robert - Kutztown, PA 19530
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Important: Live availability is not reflected. Submission provides a booking request, not a confirmed time.

Call For Same Day Service/Emergencies at 484-646-3363 .

By pressing Submit I agree to receive phone, email, or text messages from Moyer Total Indoor Comfort to the provided mobile number and also agree to the Moyer Total Indoor Comfort terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next