Specials Call Now Contact Us Book Online

HVAC & Plumbing Services in Fleetwood, PA

moyer-bull-dog-with-red-stripe

Expert HVAC & Plumbing Services for Fleetwood, PA Homes

If you live in Fleetwood, PA, you know the value of having a home that stays comfortable year-round. Whether you're looking for reliable heating solutions during the cold winters or need a cool escape from the summer heat, Moyer Total Indoor Comfort is here to ensure your home remains a haven of comfort. For over a century, we've been the trusted provider of Fleetwood heating and cooling services, offering unparalleled expertise and service in both HVAC and plumbing solutions.

Fleetwood Heating And Cooling

Your Go-To Source for Fleetwood Heating and Cooling

At Moyer Total Indoor Comfort, we understand that the right heating and cooling solutions are crucial for maintaining a comfortable living space in Fleetwood. Our experienced technicians are trained to handle everything from quick repairs to full system installations. Whether it's installing a new furnace in the winter or repairing an air conditioner in the summer, we make sure your system runs efficiently all year long.

If you're looking to upgrade your current system, we offer a wide selection of energy-efficient heating and cooling systems designed to save you money on energy bills while providing reliable comfort. Our team will guide you through the best options for your home’s unique needs and ensure the installation is seamless and hassle-free.

Comprehensive HVAC & Plumbing Services

We don’t just stop at heating and cooling—we also offer a full range of HVAC and plumbing services. From water heater installations to drain cleaning and water filtration solutions, our team can help with all your home comfort needs. You can trust us to handle your plumbing systems with the same care and expertise we apply to our HVAC work.

Whether you need HVAC repairs, routine maintenance, or a completely new installation, Moyer Total Indoor Comfort is the company to call. Our plumbers are ready to assist with everything from fixing leaks to installing new fixtures. As a family-owned business serving Fleetwood for over 100 years, we pride ourselves on offering the highest quality services.

For more information about our Fleetwood heating and cooling services, visit our contact page or call us directly at 484-646-3363. We are always happy to answer any questions and schedule a service appointment at your convenience.

Why Choose Moyer Total Indoor Comfort for Fleetwood Heating and Cooling?

When it comes to maintaining a comfortable home in Fleetwood, choosing the right provider makes all the difference. At Moyer Total Indoor Comfort, we stand out for our:

  • Decades of Experience: With over 100 years of experience, we bring knowledge and skill to every job.
  • Reliable Service: Our team is dedicated to providing prompt and reliable services that meet the highest standards of quality.
  • Comprehensive Services: We offer both HVAC and plumbing services, ensuring that all your home comfort needs are covered.
  • Personalized Solutions: We take the time to assess your home’s specific needs and recommend the best products and services for you.
  • Customer Satisfaction: We treat our customers like family and are committed to ensuring your complete satisfaction with our work.

Breathe Easier with Indoor Air Quality Solutions

Fleetwood Heating And Cooling Services

At Moyer Total Indoor Comfort, we know that true comfort means more than just the right temperature. It also means breathing clean, healthy air. That’s why we offer advanced indoor air quality solutions, including:

  • Air filtration systems
  • Humidity control
  • UV air purifiers
  • Duct cleaning

These solutions help ensure that the air in your home is free from allergens, dust, and other contaminants, providing you and your family with a healthier living environment.

Get in Touch with Us Today!

Fleetwood Heating And Cooling Repair

At Moyer Total Indoor Comfort, we’re proud to serve the Fleetwood, PA community with reliable HVAC and plumbing services. We understand that your home’s comfort is a priority, and our team is here to ensure your systems work efficiently year-round.

If you’re in need of Fleetwood heating and cooling services, don’t hesitate to reach out to us! Visit our contact page to get in touch or call 484-646-3363 to schedule a service today.

Recent Jobs and Reviews in Fleetwood, PA

Rated 5.0 out of 5 stars based on 11 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction with the service provided. Customers consistently express appreciation for the professionalism, knowledge, and expertise demonstrated by the technicians. A dominant theme throughout the feedback is the thoroughness of the work performed, with many reviewers highlighting how technicians took time to explain procedures, share findings, and provide clear communication about repairs and systems. The use of visual aids, such as pictures showing before-and-after work, is particularly appreciated and contributes to customer confidence in the service quality. Punctuality and efficiency emerge as recurring positive attributes, with customers noting timely arrivals, quick diagnoses, and repairs completed within reasonable timeframes. The courteous and friendly demeanor of service personnel is frequently mentioned, creating a welcoming and professional experience. Customers express satisfaction with the reliability of the company, indicating trust built through consistent quality service and successful problem resolution. The ability to handle various tasks—from HVAC repairs and installations to plumbing issues—demonstrates versatility that customers value. Overall, the reviews convey a sense of confidence and appreciation, with many customers expressing intent to continue using the service and recommending it based on their positive experiences. The tone is decidedly positive, reflecting a customer base that feels well-served and respected.

Job Locations and Reviews

Review
Both guys who serviced my a/c unit were helpful, friendly and knowledgeable. Felt very much like I could trust what they did and what they told me.
Carol - Fleetwood, PA 19522
Completed comprehensive air conditioning tune-up and maintenance on existing residential cooling system, approximately 5 years old. Performed standard diagnostic testing using Fieldpiece SC260 multimeter, measuring electrical parameters including voltage and capacitance readings to verify proper system operation. All components inspected and system operating within normal specifications.
Completed comprehensive air conditioning tune-up and maintenance on existing residential cooling system, approximately 5 years old. Performed standard diagnostic testing using Fieldpiece SC260 multimeter, measuring electrical parameters including voltage and capacitance readings to verify proper system operation. All components inspected and system operating within normal specifications.
Bob L.
Bob L. Checked in
Completed comprehensive air conditioning tune-up and maintenance on existing residential cooling system, approximately 5 years old. Performed standard diagnostic testing using Fieldpiece SC260 multimeter, measuring electrical parameters including voltage and capacitance readings to verify proper system operation. All components inspected and system operating within normal specifications.
Fleetwood, PA 19522
Responded to customer complaint of toilet whistling when flushed and constant dripping into bowl. Upon inspection, found deteriorated fill valve assembly with mineral buildup and sediment accumulation throughout tank interior. Identified faulty fill valve causing whistling noise and defective flush valve allowing continuous water seepage into bowl. Documented existing conditions showing significant mineral deposits, rust-colored staining, and discolored water indicating aged components requiring replacement to restore proper operation and eliminate water waste.
Responded to customer complaint of toilet whistling when flushed and constant dripping into bowl. Upon inspection, found deteriorated fill valve assembly with mineral buildup and sediment accumulation throughout tank interior. Identified faulty fill valve causing whistling noise and defective flush valve allowing continuous water seepage into bowl. Documented existing conditions showing significant mineral deposits, rust-colored staining, and discolored water indicating aged components requiring replacement to restore proper operation and eliminate water waste.
Jonathan K.
Jonathan K. Checked in
Responded to customer complaint of toilet whistling when flushed and constant dripping into bowl. Upon inspection, found deteriorated fill valve assembly with mineral buildup and sediment accumulation throughout tank interior. Identified faulty fill valve causing whistling noise and defective flush valve allowing continuous water seepage into bowl. Documented existing conditions showing significant mineral deposits, rust-colored staining, and discolored water indicating aged components requiring replacement to restore proper operation and eliminate water waste.
Fleetwood, PA 19522
Review
Very efficient installation of water softener, filter, and tank.
Maureen - Fleetwood, PA 19522
Completed comprehensive water treatment system installation including Hague water softener, WR-120 well water storage tank, and whole house filtration system on main water supply line. All equipment installed with copper piping connections in confined utility space, with proper integration to existing plumbing infrastructure. System tested and operational upon completion.
Completed comprehensive water treatment system installation including Hague water softener, WR-120 well water storage tank, and whole house filtration system on main water supply line. All equipment installed with copper piping connections in confined utility space, with proper integration to existing plumbing infrastructure. System tested and operational upon completion.
Adam M.
Adam M. Checked in
Completed comprehensive water treatment system installation including Hague water softener, WR-120 well water storage tank, and whole house filtration system on main water supply line. All equipment installed with copper piping connections in confined utility space, with proper integration to existing plumbing infrastructure. System tested and operational upon completion.
Fleetwood, PA 19522
Review
Technician Roberto was very knowledgeable and honest.
Michael - Fleetwood, PA 19522
Completed comprehensive maintenance inspection on 3-year-old heat pump system. Performed electrical diagnostics using clamp meter on indoor air handler unit, measuring blower motor amperage at 5.92 amps, confirming proper operation within manufacturer specifications. Proceeded to outdoor condensing unit where capacitor testing was conducted, measuring 3299 microfarads to verify component integrity and starting capabilities. All electrical connections inspected and found secure, system operating efficiently with no issues identified.
Completed comprehensive maintenance inspection on 3-year-old heat pump system. Performed electrical diagnostics using clamp meter on indoor air handler unit, measuring blower motor amperage at 5.92 amps, confirming proper operation within manufacturer specifications. Proceeded to outdoor condensing unit where capacitor testing was conducted, measuring 3299 microfarads to verify component integrity and starting capabilities. All electrical connections inspected and found secure, system operating efficiently with no issues identified.
Roberto H.
Roberto H. Checked in
Completed comprehensive maintenance inspection on 3-year-old heat pump system. Performed electrical diagnostics using clamp meter on indoor air handler unit, measuring blower motor amperage at 5.92 amps, confirming proper operation within manufacturer specifications. Proceeded to outdoor condensing unit where capacitor testing was conducted, measuring 3299 microfarads to verify component integrity and starting capabilities. All electrical connections inspected and found secure, system operating efficiently with no issues identified.
Fleetwood, PA 19522
Review
Excellent Service
Mike - Fleetwood, PA 19522
Fleetwood, PA - Responded to no cooling complaint on Carrier heat pump system installed in 2002. Upon arrival, diagnosed indoor blower motor failure preventing air circulation. Replaced defective blower motor with new unit and verified proper operation. Inspected heavily soiled air filters showing significant dust and debris accumulation, recommended immediate replacement to prevent future system issues and maintain proper airflow. System restored to full cooling operation and tested for proper function.
Bob L.
Bob L. Checked in
Responded to no cooling complaint on Carrier heat pump system installed in 2002. Upon arrival, diagnosed indoor blower motor failure preventing air circulation. Replaced defective blower motor with new unit and verified proper operation. Inspected heavily soiled air filters showing significant dust and debris accumulation, recommended immediate replacement to prevent future system issues and maintain proper airflow. System restored to full cooling operation and tested for proper function.
Fleetwood, PA 19522
Responded to troubleshoot ongoing water system issues including recurring low water pressure, filter contamination with black sediment, and persistent leaking at the whole house water filter assembly. Conducted comprehensive inspection of the complete water system from well to point-of-entry equipment, examining all plumbing connections, pressure regulation components, and filtration hardware. Documented existing conditions with photographs showing the insulated pipe network, pressure gauge, filter housing with visible leak collection pans positioned beneath the assembly, and associated water treatment components. Identified the whole house filter as the primary source of leaking, which had progressed from an initial leak that temporarily stopped after filter replacement to a current slow drip condition. Noted significant black sediment accumulation requiring multiple filter changes within a short timeframe, indicating potential issues with well water quality or system contamination. E
Responded to troubleshoot ongoing water system issues including recurring low water pressure, filter contamination with black sediment, and persistent leaking at the whole house water filter assembly. Conducted comprehensive inspection of the complete water system from well to point-of-entry equipment, examining all plumbing connections, pressure regulation components, and filtration hardware. Documented existing conditions with photographs showing the insulated pipe network, pressure gauge, filter housing with visible leak collection pans positioned beneath the assembly, and associated water treatment components. Identified the whole house filter as the primary source of leaking, which had progressed from an initial leak that temporarily stopped after filter replacement to a current slow drip condition. Noted significant black sediment accumulation requiring multiple filter changes within a short timeframe, indicating potential issues with well water quality or system contamination. E
Adam M.
Adam M. Checked in
Responded to troubleshoot ongoing water system issues including recurring low water pressure, filter contamination with black sediment, and persistent leaking at the whole house water filter assembly. Conducted comprehensive inspection of the complete water system from well to point-of-entry equipment, examining all plumbing connections, pressure regulation components, and filtration hardware. Documented existing conditions with photographs showing the insulated pipe network, pressure gauge, filter housing with visible leak collection pans positioned beneath the assembly, and associated water treatment components. Identified the whole house filter as the primary source of leaking, which had progressed from an initial leak that temporarily stopped after filter replacement to a current slow drip condition. Noted significant black sediment accumulation requiring multiple filter changes within a short timeframe, indicating potential issues with well water quality or system contamination. E
Fleetwood, PA 19522
Completed comprehensive air conditioning tune-up and maintenance on existing residential system approximately 3-4 years old. Performed standard inspection procedures including refrigerant level check, electrical component testing, condensate drain verification, air filter assessment, and overall system performance evaluation. All components found to be operating within normal parameters with no issues identified or repairs required.
Completed comprehensive air conditioning tune-up and maintenance on existing residential system approximately 3-4 years old. Performed standard inspection procedures including refrigerant level check, electrical component testing, condensate drain verification, air filter assessment, and overall system performance evaluation. All components found to be operating within normal parameters with no issues identified or repairs required.
Adam M.
Adam M. Checked in
Completed comprehensive air conditioning tune-up and maintenance on existing residential system approximately 3-4 years old. Performed standard inspection procedures including refrigerant level check, electrical component testing, condensate drain verification, air filter assessment, and overall system performance evaluation. All components found to be operating within normal parameters with no issues identified or repairs required.
Fleetwood, PA 19522
Review
We have a Diakon mini split and we're told by another "reputable" HVAC company that the part for repair was obsolete. Moyers HVAC looked at the questionable problem and told us that the part is available and will be doing the repair. I have always been an advocate of using family owned local businesses, Moyers has proved this to certainly be the best choice, and will continue to work with Moyers Total Indoor Comfort in Kutztown, without a doubt.
Don Miller - Fleetwood, PA 19522
Responded to service call for Daikin ductless mini-split system with four indoor heads. Inspected largest head unit located in dining room with reported louver malfunction. Confirmed horizontal venting option inoperative while vertical positioning remains functional, indicating internal louver gear mechanism failure. Upon opening unit for inspection, discovered significant dust and lint accumulation on internal components and blower assembly, which can contribute to mechanical binding and premature wear of moving parts. System otherwise operating normally with adequate cooling performance. Discussed repair options with customer, including louver motor/gear assembly replacement. Noted unit age at 15-20 years and discussed system obsolescence concerns. Customer aware that replacement parts availability may be limited due to age of equipment. System continues to provide cooling function with vertical airflow direction. Recommended monitoring system performance and provided options for rep
Responded to service call for Daikin ductless mini-split system with four indoor heads. Inspected largest head unit located in dining room with reported louver malfunction. Confirmed horizontal venting option inoperative while vertical positioning remains functional, indicating internal louver gear mechanism failure. Upon opening unit for inspection, discovered significant dust and lint accumulation on internal components and blower assembly, which can contribute to mechanical binding and premature wear of moving parts. System otherwise operating normally with adequate cooling performance. Discussed repair options with customer, including louver motor/gear assembly replacement. Noted unit age at 15-20 years and discussed system obsolescence concerns. Customer aware that replacement parts availability may be limited due to age of equipment. System continues to provide cooling function with vertical airflow direction. Recommended monitoring system performance and provided options for rep
Bob L.
Bob L. Checked in
Responded to service call for Daikin ductless mini-split system with four indoor heads. Inspected largest head unit located in dining room with reported louver malfunction. Confirmed horizontal venting option inoperative while vertical positioning remains functional, indicating internal louver gear mechanism failure. Upon opening unit for inspection, discovered significant dust and lint accumulation on internal components and blower assembly, which can contribute to mechanical binding and premature wear of moving parts. System otherwise operating normally with adequate cooling performance. Discussed repair options with customer, including louver motor/gear assembly replacement. Noted unit age at 15-20 years and discussed system obsolescence concerns. Customer aware that replacement parts availability may be limited due to age of equipment. System continues to provide cooling function with vertical airflow direction. Recommended monitoring system performance and provided options for rep
Fleetwood, PA 19522
Performed comprehensive air conditioning tune-up and maintenance on Rheem system installed in October 2016. Completed inspection of outdoor condenser unit, cleaned outdoor coil, and verified proper system operation. Also conducted gas furnace tune-up on matching Rheem equipment from same installation date, with last service performed in September 2021. Noted previous observation of potential water heater leak that requires further investigation when area around unit is accessible for proper assessment.
Performed comprehensive air conditioning tune-up and maintenance on Rheem system installed in October 2016. Completed inspection of outdoor condenser unit, cleaned outdoor coil, and verified proper system operation. Also conducted gas furnace tune-up on matching Rheem equipment from same installation date, with last service performed in September 2021. Noted previous observation of potential water heater leak that requires further investigation when area around unit is accessible for proper assessment.
Adam M.
Adam M. Checked in
Performed comprehensive air conditioning tune-up and maintenance on Rheem system installed in October 2016. Completed inspection of outdoor condenser unit, cleaned outdoor coil, and verified proper system operation. Also conducted gas furnace tune-up on matching Rheem equipment from same installation date, with last service performed in September 2021. Noted previous observation of potential water heater leak that requires further investigation when area around unit is accessible for proper assessment.
Fleetwood, PA 19522
Responded to call regarding leaking outdoor hydrant at front of property. Upon arrival, confirmed hydrant had been shut off by customer to prevent further water loss. Inspected exterior hose bib and surrounding mounting area, noting weathered concrete block installation and aged hardware components. Assessed condition of hydrant assembly, mounting brackets, and connection points for source of leak. Documented existing conditions showing significant weathering and deterioration of mounting structure and hardware. Secured hydrant assembly and verified water supply remained in off position to prevent additional leakage until permanent repairs could be scheduled.
Responded to call regarding leaking outdoor hydrant at front of property. Upon arrival, confirmed hydrant had been shut off by customer to prevent further water loss. Inspected exterior hose bib and surrounding mounting area, noting weathered concrete block installation and aged hardware components. Assessed condition of hydrant assembly, mounting brackets, and connection points for source of leak. Documented existing conditions showing significant weathering and deterioration of mounting structure and hardware. Secured hydrant assembly and verified water supply remained in off position to prevent additional leakage until permanent repairs could be scheduled.
Jonathan K.
Jonathan K. Checked in
Responded to call regarding leaking outdoor hydrant at front of property. Upon arrival, confirmed hydrant had been shut off by customer to prevent further water loss. Inspected exterior hose bib and surrounding mounting area, noting weathered concrete block installation and aged hardware components. Assessed condition of hydrant assembly, mounting brackets, and connection points for source of leak. Documented existing conditions showing significant weathering and deterioration of mounting structure and hardware. Secured hydrant assembly and verified water supply remained in off position to prevent additional leakage until permanent repairs could be scheduled.
Fleetwood, PA 19522
Review
Great Service
Lisa - Fleetwood, PA 19522
Completed comprehensive air conditioning maintenance inspection and tune-up service. Upon inspection, discovered significant mold and biological growth contamination throughout the blower assembly and interior housing components, indicating moisture intrusion and inadequate previous maintenance. Documented system condition with photographic evidence showing extensive discoloration on blower wheel housing and surrounding metal surfaces, presenting potential air quality concerns that will require additional remediation services beyond standard maintenance scope.
Completed comprehensive air conditioning maintenance inspection and tune-up service. Upon inspection, discovered significant mold and biological growth contamination throughout the blower assembly and interior housing components, indicating moisture intrusion and inadequate previous maintenance. Documented system condition with photographic evidence showing extensive discoloration on blower wheel housing and surrounding metal surfaces, presenting potential air quality concerns that will require additional remediation services beyond standard maintenance scope.
Adam M.
Adam M. Checked in
Completed comprehensive air conditioning maintenance inspection and tune-up service. Upon inspection, discovered significant mold and biological growth contamination throughout the blower assembly and interior housing components, indicating moisture intrusion and inadequate previous maintenance. Documented system condition with photographic evidence showing extensive discoloration on blower wheel housing and surrounding metal surfaces, presenting potential air quality concerns that will require additional remediation services beyond standard maintenance scope.
Fleetwood, PA 19522
Completed installation of Daikin Aurora Extreme ductless heat pump system with three indoor units featuring brown and ivory slim duct configurations. Added supplemental heating zone to existing oil boiler system and installed 40-gallon Crown Mega-Stor indirect water heater to provide domestic hot water, integrating all systems for optimal heating and cooling performance throughout the property.
Completed installation of Daikin Aurora Extreme ductless heat pump system with three indoor units featuring brown and ivory slim duct configurations. Added supplemental heating zone to existing oil boiler system and installed 40-gallon Crown Mega-Stor indirect water heater to provide domestic hot water, integrating all systems for optimal heating and cooling performance throughout the property.
Bob L.
Bob L. Checked in
Completed installation of Daikin Aurora Extreme ductless heat pump system with three indoor units featuring brown and ivory slim duct configurations. Added supplemental heating zone to existing oil boiler system and installed 40-gallon Crown Mega-Stor indirect water heater to provide domestic hot water, integrating all systems for optimal heating and cooling performance throughout the property.
Fleetwood, PA 19522
Completed CPM A/C inspection on main heat pump system and follow-up installation check on Daikin ductless mini-split system serving sunroom area. Addressed issue with main unit not turning off properly, verified airflow direction on air handler Model 449, and inspected outdoor disconnect and electrical components. Delivered installation packet that was missed during initial system installation.
Completed CPM A/C inspection on main heat pump system and follow-up installation check on Daikin ductless mini-split system serving sunroom area. Addressed issue with main unit not turning off properly, verified airflow direction on air handler Model 449, and inspected outdoor disconnect and electrical components. Delivered installation packet that was missed during initial system installation.
Adam M.
Adam M. Checked in
Completed CPM A/C inspection on main heat pump system and follow-up installation check on Daikin ductless mini-split system serving sunroom area. Addressed issue with main unit not turning off properly, verified airflow direction on air handler Model 449, and inspected outdoor disconnect and electrical components. Delivered installation packet that was missed during initial system installation.
Fleetwood, PA 19522
Completed preventative maintenance inspection on existing Goodman air conditioning system. Performed comprehensive system evaluation including temperature differential measurements across evaporator coil, recording 53.8°F reading at unit. Conducted electrical diagnostics using clamp meter, measuring capacitance at 487 MFD to verify compressor capacitor performance within manufacturer specifications. Inspected condenser coil condition, noting dust accumulation on fins. All electrical connections verified secure, system operating within normal parameters.
Completed preventative maintenance inspection on existing Goodman air conditioning system. Performed comprehensive system evaluation including temperature differential measurements across evaporator coil, recording 53.8°F reading at unit. Conducted electrical diagnostics using clamp meter, measuring capacitance at 487 MFD to verify compressor capacitor performance within manufacturer specifications. Inspected condenser coil condition, noting dust accumulation on fins. All electrical connections verified secure, system operating within normal parameters.
Roberto H.
Roberto H. Checked in
Completed preventative maintenance inspection on existing Goodman air conditioning system. Performed comprehensive system evaluation including temperature differential measurements across evaporator coil, recording 53.8°F reading at unit. Conducted electrical diagnostics using clamp meter, measuring capacitance at 487 MFD to verify compressor capacitor performance within manufacturer specifications. Inspected condenser coil condition, noting dust accumulation on fins. All electrical connections verified secure, system operating within normal parameters.
Fleetwood, PA 19522
Responded to no hot water complaint on oil-fired boiler system. Upon arrival, inspected boiler unit and associated hydronic piping system. Found low system water pressure affecting boiler operation. Checked expansion tank, circulator, and zone valves for proper function. Addressed water pressure issue by adding water to system and purging air from lines. Verified boiler firing sequence, burner operation, and flame characteristics. Confirmed domestic hot water production restored and system operating within normal parameters. Advised customer regarding low water pressure throughout house plumbing system requiring attention to house water filter.
Responded to no hot water complaint on oil-fired boiler system. Upon arrival, inspected boiler unit and associated hydronic piping system. Found low system water pressure affecting boiler operation. Checked expansion tank, circulator, and zone valves for proper function. Addressed water pressure issue by adding water to system and purging air from lines. Verified boiler firing sequence, burner operation, and flame characteristics. Confirmed domestic hot water production restored and system operating within normal parameters. Advised customer regarding low water pressure throughout house plumbing system requiring attention to house water filter.
Bob L.
Bob L. Checked in
Responded to no hot water complaint on oil-fired boiler system. Upon arrival, inspected boiler unit and associated hydronic piping system. Found low system water pressure affecting boiler operation. Checked expansion tank, circulator, and zone valves for proper function. Addressed water pressure issue by adding water to system and purging air from lines. Verified boiler firing sequence, burner operation, and flame characteristics. Confirmed domestic hot water production restored and system operating within normal parameters. Advised customer regarding low water pressure throughout house plumbing system requiring attention to house water filter.
Fleetwood, PA 19522
Review
Excellent service! Very personable
Janis - Fleetwood, PA 19522
Completed comprehensive air conditioning tune-up and maintenance inspection on residential HVAC system, approximately 7 years old and previously installed by third-party contractor. Performed thorough evaluation of outdoor condenser unit including fan assembly, electrical connections, and overall system operation. Inspected indoor air handler components, verified proper electrical wiring connections, and assessed control systems. Provided estimate for replacement of leaking oil filter canister identified during inspection.
Completed comprehensive air conditioning tune-up and maintenance inspection on residential HVAC system, approximately 7 years old and previously installed by third-party contractor. Performed thorough evaluation of outdoor condenser unit including fan assembly, electrical connections, and overall system operation. Inspected indoor air handler components, verified proper electrical wiring connections, and assessed control systems. Provided estimate for replacement of leaking oil filter canister identified during inspection.
Adam M.
Adam M. Checked in
Completed comprehensive air conditioning tune-up and maintenance inspection on residential HVAC system, approximately 7 years old and previously installed by third-party contractor. Performed thorough evaluation of outdoor condenser unit including fan assembly, electrical connections, and overall system operation. Inspected indoor air handler components, verified proper electrical wiring connections, and assessed control systems. Provided estimate for replacement of leaking oil filter canister identified during inspection.
Fleetwood, PA 19522
Completed preventive maintenance inspection on Carrier heat pump system installed in June 2020. Performed comprehensive tune-up including electrical measurements at supply register, visual inspection of air handler unit, and verification of refrigerant lines and electrical connections. All components found operating within normal parameters.
Completed preventive maintenance inspection on Carrier heat pump system installed in June 2020. Performed comprehensive tune-up including electrical measurements at supply register, visual inspection of air handler unit, and verification of refrigerant lines and electrical connections. All components found operating within normal parameters.
Roberto H.
Roberto H. Checked in
Completed preventive maintenance inspection on Carrier heat pump system installed in June 2020. Performed comprehensive tune-up including electrical measurements at supply register, visual inspection of air handler unit, and verification of refrigerant lines and electrical connections. All components found operating within normal parameters.
Fleetwood, PA 19522
Responded to no cooling complaint with indoor fan and outdoor unit running but no cold air production. Performed diagnostic testing and measured supply air temperature at 88.8°F, confirming lack of cooling. Identified failed capacitor with discolored and deteriorated wiring connections. Replaced defective capacitor, verified proper electrical connections, and restored system to normal cooling operation.
Responded to no cooling complaint with indoor fan and outdoor unit running but no cold air production. Performed diagnostic testing and measured supply air temperature at 88.8°F, confirming lack of cooling. Identified failed capacitor with discolored and deteriorated wiring connections. Replaced defective capacitor, verified proper electrical connections, and restored system to normal cooling operation.
Roberto H.
Roberto H. Checked in
Responded to no cooling complaint with indoor fan and outdoor unit running but no cold air production. Performed diagnostic testing and measured supply air temperature at 88.8°F, confirming lack of cooling. Identified failed capacitor with discolored and deteriorated wiring connections. Replaced defective capacitor, verified proper electrical connections, and restored system to normal cooling operation.
Fleetwood, PA 19522
Responded to service call for downstairs HVAC unit that would not turn on. Upon arrival, found thermostat displaying "System: Wait" status, indicating a safety delay timer was active. Inspected 9-year-old heat pump system including outdoor condenser unit and indoor components. Replaced air filters on both upstairs and downstairs HVAC units as requested. Verified outdoor condenser unit fan assembly and protective guard were intact and functioning properly. System resumed normal operation after safety timer cycle completed.
Responded to service call for downstairs HVAC unit that would not turn on. Upon arrival, found thermostat displaying "System: Wait" status, indicating a safety delay timer was active. Inspected 9-year-old heat pump system including outdoor condenser unit and indoor components. Replaced air filters on both upstairs and downstairs HVAC units as requested. Verified outdoor condenser unit fan assembly and protective guard were intact and functioning properly. System resumed normal operation after safety timer cycle completed.
Adam M.
Adam M. Checked in
Responded to service call for downstairs HVAC unit that would not turn on. Upon arrival, found thermostat displaying "System: Wait" status, indicating a safety delay timer was active. Inspected 9-year-old heat pump system including outdoor condenser unit and indoor components. Replaced air filters on both upstairs and downstairs HVAC units as requested. Verified outdoor condenser unit fan assembly and protective guard were intact and functioning properly. System resumed normal operation after safety timer cycle completed.
Fleetwood, PA 19522
Review
Annual check up
Robert - Fleetwood, PA 19522
Completed comprehensive air conditioning tune-up on existing Trane system installed in December 2021. Inspected capacitor, verified electrical connections, and assessed overall system performance. Supplied and installed 20x20x4 air filter as previously arranged during last year's maintenance visit.
Completed comprehensive air conditioning tune-up on existing Trane system installed in December 2021. Inspected capacitor, verified electrical connections, and assessed overall system performance. Supplied and installed 20x20x4 air filter as previously arranged during last year's maintenance visit.
Adam M.
Adam M. Checked in
Completed comprehensive air conditioning tune-up on existing Trane system installed in December 2021. Inspected capacitor, verified electrical connections, and assessed overall system performance. Supplied and installed 20x20x4 air filter as previously arranged during last year's maintenance visit.
Fleetwood, PA 19522
Jonathan K.
Jonathan K. Checked in
Replace laundry, shut off valve
Fleetwood, PA 19522
Performed comprehensive oil heating system cleaning and tune-up on Buderus unit at rental property. Completed full maintenance service including burner cleaning, nozzle inspection (60 X 60A), combustion analysis, and system safety checks. Unit last serviced in October 2024; all components inspected, cleaned, and verified for proper operation to ensure reliable heating performance.
Performed comprehensive oil heating system cleaning and tune-up on Buderus unit at rental property. Completed full maintenance service including burner cleaning, nozzle inspection (60 X 60A), combustion analysis, and system safety checks. Unit last serviced in October 2024; all components inspected, cleaned, and verified for proper operation to ensure reliable heating performance.
Adam M.
Adam M. Checked in
Performed comprehensive oil heating system cleaning and tune-up on Buderus unit at rental property. Completed full maintenance service including burner cleaning, nozzle inspection (60 X 60A), combustion analysis, and system safety checks. Unit last serviced in October 2024; all components inspected, cleaned, and verified for proper operation to ensure reliable heating performance.
Fleetwood, PA 19522
Responded to dispatch for continuously running toilet on ground floor unit. Upon inspection, removed tank cover and found fill valve assembly requiring adjustment. Adjusted standpipe height to correct water level. Tank interior showed extensive rust staining, mineral deposits, and mold growth indicating long-term water exposure and lack of maintenance. Fill valve with red cap and float mechanism were functional but corroded. Black rubber flapper and chain assembly showed signs of deterioration. After adjustment, toilet continued running, indicating additional repair needs beyond initial standpipe adjustment. Tank cover could not be properly reinstalled due to component interference. Documented tank condition showing heavy rust on porcelain surfaces, corroded brass fittings, discolored water, and significant biological growth along tank rim requiring comprehensive cleaning and potential component replacement for complete repair.
Responded to dispatch for continuously running toilet on ground floor unit. Upon inspection, removed tank cover and found fill valve assembly requiring adjustment. Adjusted standpipe height to correct water level. Tank interior showed extensive rust staining, mineral deposits, and mold growth indicating long-term water exposure and lack of maintenance. Fill valve with red cap and float mechanism were functional but corroded. Black rubber flapper and chain assembly showed signs of deterioration. After adjustment, toilet continued running, indicating additional repair needs beyond initial standpipe adjustment. Tank cover could not be properly reinstalled due to component interference. Documented tank condition showing heavy rust on porcelain surfaces, corroded brass fittings, discolored water, and significant biological growth along tank rim requiring comprehensive cleaning and potential component replacement for complete repair.
Jonathan K.
Jonathan K. Checked in
Responded to dispatch for continuously running toilet on ground floor unit. Upon inspection, removed tank cover and found fill valve assembly requiring adjustment. Adjusted standpipe height to correct water level. Tank interior showed extensive rust staining, mineral deposits, and mold growth indicating long-term water exposure and lack of maintenance. Fill valve with red cap and float mechanism were functional but corroded. Black rubber flapper and chain assembly showed signs of deterioration. After adjustment, toilet continued running, indicating additional repair needs beyond initial standpipe adjustment. Tank cover could not be properly reinstalled due to component interference. Documented tank condition showing heavy rust on porcelain surfaces, corroded brass fittings, discolored water, and significant biological growth along tank rim requiring comprehensive cleaning and potential component replacement for complete repair.
Fleetwood, PA 19522
Responded to heating system service call and found the ventilation panel had detached from the oil heating unit and was lying on the floor. Inspected the heat exchanger assembly, which showed significant mineral deposits, scale buildup, and corrosion throughout the component and surrounding frame, indicating extended service life and moisture exposure. Documented the condition of the system with photographs showing the deteriorated ventilation panel with accumulated dust and debris, as well as the heavily scaled burner assembly with corrosion around circular openings and ductwork connections.
Responded to heating system service call and found the ventilation panel had detached from the oil heating unit and was lying on the floor. Inspected the heat exchanger assembly, which showed significant mineral deposits, scale buildup, and corrosion throughout the component and surrounding frame, indicating extended service life and moisture exposure. Documented the condition of the system with photographs showing the deteriorated ventilation panel with accumulated dust and debris, as well as the heavily scaled burner assembly with corrosion around circular openings and ductwork connections.
Bob L.
Bob L. Checked in
Responded to heating system service call and found the ventilation panel had detached from the oil heating unit and was lying on the floor. Inspected the heat exchanger assembly, which showed significant mineral deposits, scale buildup, and corrosion throughout the component and surrounding frame, indicating extended service life and moisture exposure. Documented the condition of the system with photographs showing the deteriorated ventilation panel with accumulated dust and debris, as well as the heavily scaled burner assembly with corrosion around circular openings and ductwork connections.
Fleetwood, PA 19522
Completed installation of Daikin Aurora ductless heat pump system for sunroom application. Mounted indoor air handler unit on interior wall, installed outdoor disconnect box with proper electrical connections, and commissioned system for operation.
Completed installation of Daikin Aurora ductless heat pump system for sunroom application. Mounted indoor air handler unit on interior wall, installed outdoor disconnect box with proper electrical connections, and commissioned system for operation.
Bob L.
Bob L. Checked in
Completed installation of Daikin Aurora ductless heat pump system for sunroom application. Mounted indoor air handler unit on interior wall, installed outdoor disconnect box with proper electrical connections, and commissioned system for operation.
Fleetwood, PA 19522
Review
Good job
John - Fleetwood, PA 19522
Review
Everyone we’ve interacted with has been kind and helpful. From estimate to office to installation. I ask a lot of questions and they never seemed bothered by them. They were great about providing additional information so I could understand what they were doing. They were prompt and affordable. Adam and Wyatt were the techs and were knowledgeable, professional, and conscientious. We just had a hot water heater installed and will be reaching out to them in the future for quotes on other HVAC needs.
Linda - Fleetwood, PA 19522
Review
Steve, nick, and Roberto did a great job very clean came on time, removed our old boiler, installed new system cleaned up and were done in 1 day my wife and me are very happy with work thx. Karen and Scott matika fleetwood pa.
Scott - Fleetwood, PA 19522
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Important: Live availability is not reflected. Submission provides a booking request, not a confirmed time.

Call For Same Day Service/Emergencies at 484-646-3363 .

By pressing Submit I agree to receive phone, email, or text messages from Moyer Total Indoor Comfort to the provided mobile number and also agree to the Moyer Total Indoor Comfort terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next